Problem Backlight Monitor Schneider XBTGT5330

Problem Backlight Monitor Schneider XBTGT5330

Problem Backlight Monitor Schneider XBTGT5330

Specification Equipment:

Color Touch Panel TFT 10,4”.

  • Brand Schneider Electric .
  • Model XBTGT5330 1 Unit.
  • Power 24VDC; 1,22A 1 Unit.

PSU Backlight.

  • Brand TDK .
  • Type PCU-P159A 

Error Issue

  • Backlight Display is Not bright so the screen is not looked ( Display monitoring in Wheelhouse)

Solution Resulting :

1. Check backlight lamp.

  • Backlight lamp must be replaced due to a short circuit,

2. Check Inverter unit

  • Inverter unit must be replaced due to damage components caused by a short circuit occurs in the backlight.

Action Taken

1. Backlight Unit

  • Has done a broken backlight lamp replacement with a new one.
  • Using the same type as the old backlight lamp.

2. Inverter Unit

  • Repair and replacement of some components on the inverter unit has been performed.
  • Some damaged components are: high voltage capacitors, fuse control, step up transformer, and some medium voltage resistors.

3. Note:

  • Backlight test we did more than 12 hours, to ensure the components and the backlight lamp works well.